Toll Free: (800) 343-4912 • Tel: (408) 764-4042 • Fax: (503) 454-5727
Components for Other Wavelength and Divergence Ranges
The body design of the ModeMaster PC scanning head has
modular lens and detector sets that allow quick changes
to other wavelength or divergence ranges to meet your
measurement needs.
The IR body can only be used with the IR (pyroelectric - pyro)
detector and either the low-divergence or high-divergence IR
heads. The UV-VIS-NIR body, however, can be used in any of the
UV, VIS or NIR spectral regions with the appropriate detector
(silicon-Si for the UV and VIS; germanium-Ge for the NIR) and
low- or high-divergence lenses. The UV lens can be used with
the silicon detector and the VIS-NIR lens can be used with
either the silicon or germanium detector.
Body
P
y
r
o
IR
Lens Tube
Detector
Lens Tube Extension
Body
Si
Ge
Visible
Lens Tube
Detector
UV
VIS
NIR
Low-Divergence Lens
Low-Divergence Lens (IR)
IR
High-Divergence Lens (IR)
High-Divergence Lens
(UV or VIS-NIR)
(UV or VIS-NIR)
+
Laser
Cross-
Reference
Index
POWER
& ENERGY
Power
Sensors
Energy
Sensors
Custom
& OEM
BEAM
DIAGNOSTICS
CALIBRATION
& SERVICE
INDICES
Product
Name
Index
Power
& Energy
Meters
Part Number Description Spectral Range
33-1843-000 ModeMaster PC System
1
UV, Low-Divergence
33-2106-000 ModeMaster PC System
1
UV, High-Divergence
33-2221-000 ModeMaster PC System
1
VIS, Low-Divergence
33-2239-000 ModeMaster PC System
1
VIS, High-Divergence
33-2387-000 ModeMaster PC System
1
NIR, Low-Divergence
33-2395-000 ModeMaster PC System
1
NIR, High-Divergence
33-2437-000 ModeMaster PC System
1
IR, Low-Divergence
33-2429-000 ModeMaster PC System
1
IR, High-Divergence
33-1710-000 ModeMaster PC Control/Interface Console and Software
ModeMaster PC M
2
Beam Propagation Analyzer (standard system conguration)
Complete Geometric Beam Characterization Along the Laser Beam Path
ModeMaster PC
Part Number Description Spectral Region(s) Scan Head Body
33-2072-000 Silicon Detector (0.22 to 1.0 µm) UV, VIS UV-VIS-NIR
33-2080-000 Germanium Detector (0.8 to 1.8 µm) NIR UV-VIS-NIR
33-2098-000 Pyroelectric Detector (1.8 to 20 µm) IR IR
33-2114-000 High-Divergence Lens Kit UV UV-VIS-NIR
33-2130-000 Low-Divergence Lens Kit UV UV-VIS-NIR
33-2122-000 High-Divergence Lens Kit VIS, NIR UV-VIS-NIR
33-2148-000 Low-Divergence Lens Kit VIS, NIR UV-VIS-NIR
33-2155-000 High-Divergence Lens Kit IR IR
33-2166-000 Low-Divergence Lens Kit IR IR
1
All ModeMaster systems include scan head, mount, control/interface console and software.